测试结果表格:
序号
|
Fullscale
Amplitude(V)
|
Input
Amplitude(V)
|
Fin(MHz)
|
Fs(MHz)
|
FFT Samples
|
SINAD
|
ENOB
|
1
|
5
|
3.94
|
1
|
7.37
|
1024
|
43.38
|
7.25
|
2
|
5
|
1.99
|
1
|
7.37
|
1024
|
37.72
|
7.30
|
3
|
0.1
|
0.078
|
1
|
7.37
|
1024
|
40.32
|
6.78
|
4
|
0.05
|
0.02
|
1
|
7.37
|
1024
|
31.80
|
6.29
|
序号
|
Fullscale
Amplitude(V)
|
Input
Amplitude(V)
|
Fin(MHz)
|
Fs(MHz)
|
FFT Samples
|
SINAD
|
ENOB
|
1
|
2.07
|
1
|
1
|
250
|
8192
|
63.23
|
11.3
|
2
|
2.07
|
1
|
20.17
|
250
|
8192
|
60.27
|
10.9
|
3
|
2.07
|
0.1
|
1
|
250
|
8192
|
46.12
|
11.7
|
4
|
2.07
|
0.1
|
20.17
|
250
|
8192
|
45.66
|
11.8
|
序号
|
Fullscale
Amplitude(V)
|
Input
Amplitude(V)
|
Fin(MHz)
|
Fs(MHz)
|
FFT Samples
|
SINAD
|
ENOB
|
1
|
2.07
|
1
|
1
|
250
|
8192
|
63.10
|
11.2
|
2
|
2.07
|
1
|
20.17
|
250
|
8192
|
60.06
|
10.8
|
3
|
2.07
|
0.1
|
1
|
250
|
8192
|
46.11
|
11.7
|
4
|
2.07
|
0.1
|
20.17
|
250
|
8192
|
45.33
|
11.7
|
对比数据可以看出,实际所测出的参数与SPEC中所给的参数还是有很大差距的,造成这个差距的主要原因为:测试环境与SPEC中可能有所不同。本测试用的信号发生器为5441,但5441的DAC也只有16位,其SFDR还没有5761的参数理想,因此使用5441来校准5761的参数会有所失真。但由于验证时未能找到有限位数更高的FGEN,因此对猜测未进行验证。
PXIe-5162 specification:http://www.ni.com/pdf/manuals/373858f.pdf
NI 5761R User Guide and Specifications:http://www.ni.com/pdf/manuals/375509a.pdf
|