"Fatal Error 9" With DAQ Tasks in Measure Primary Software: Other NI Software>>MeasurePrimary Software Version: 1.2 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: When I attempt to configure an analog output task for two channels using Measure 1.2 and Excel 7.0, I always get the error Fatal error 9 in 'InterleaveData' line #173: Subscript out of range. What can I do? Solution: This is a problem in Measure 1.2 that is fixed in the 1.2c update for Measure. This is a free update and is available for download at the URL below in the Related Links section. If you still experience this problem with Measure 1.2c (or Measure 2.0), you may want to simply re-write your DAQ Task. Sometimes whenever an Excel program is moved through different versions of Excel, the Fatal error 9 will occur. By re-writing the DAQ Task this problem should be resolved. Related Links: Measure Support Drivers and Updates: Measure 1.2c Update Attachments:
Report Date: 12/08/2000 Last Updated: 05/07/2004 Document ID: 247DOUDM |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||