Error 50151 Cuando Ejecuto el Self-Test en Measurement and Automation Explorer



Software Primario:
Versión de Software Primario: 1.0.1
Versión de Software Primario Corregido: N/A
Software Secundario: N/A
Hardware: Multifunction DAQ (MIO)

Problema:
Estoy obteniendo el Error 50151 cuando ejecuto el Self-Test en mi tarjeta PCI en Measurement and Automation Explorer.
 
Error 50151: The firmware - which is software resident on a device - has entered an unknown state usually as a result of a cascade failure induced by an unexpected series of state inputs. The operation could not be completed as specified, and you should immediately terminate all further transactions if you are able to do so.


Solución:
Para reparar este error debe mover su tarjeta a un slot PCI de 5 V.
La mayoría de los dispositivos PCI actuales soportan los estándares PCI de 5 V y PCI-X de 3.3 V, pero algunos dispositivos PCI más viejos requieren un slot PCI de 5 V. Si intenta correr uno de estos dispositivos viejos en un slot de 3.3 V recibirá el Error 50151 al correr el Self-Test en el Measurement and Automation Explorer.