AT-GPIB / Windows 95 - Win32 Compatibility Release Software RestrictionsHardware: GPIB>>Plug-in Controllers>>AT-GPIB
Problem: What are the restrictions for the AT-GPIB board with the Windows 95 Win32 Compatibility Release software? Solution: The restrictions for the Win32 Compatibility Release software are as follows: Restrictions for Data Transfers: The maximum number of bytes that you can use to transfer data is 65528 bytes (64K - 8). Restrictions for Win32 Applications: Interrupts for the 32-to-16 bit thunking DLLs must be disabled for applications to run properly. Do not use the 16-bit GPIB Spy because it causes General Protection faults if it is used to spy on Win32 GPIB applications. Note: These restrictions do NOT apply to DOS and Win16 applications. Related Links: KnowledgeBase 42BIAOD2: Windows 98/95 GPIB Compatibility Release Attachments:
Report Date: 02/01/2007 Last Updated: 02/02/2007 Document ID: 460FDSC5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||