Which Digital lines (DIO) lines on the MIO E-Series are used by the SC-2040 Simultaneous Sample/Hold Module?

Hardware: Signal Conditioning Other>>SC Analog Accessories

Problem: Which Digital lines (DIO) lines on the MIO E-Series are used by the SC-2040 Simultaneous Sample/Hold Module?

Solution: No digital lines are used. The MIO E-Series only uses lines PFI2 and PFI7 to control the SC-2040 . PFI7 is always configured for output and controls the track/hold signal. PFI2 is used only when you want to use external scan timing.