Traditional NI-DAQ (Legacy) Documentation Omits Setting for S Series Device Gain

Primary Software: Driver Software>>NI-DAQ
Primary Software Version: 7.0
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Multifunction DAQ (MIO)>>S Series

Problem: When setting the gain for S Series devices, you must pass an integer input with some of the functions. The Traditional NI-DAQ (Legacy) Function Reference Help does not indicate which integer input to set to achieve a gain of .2 for S Series devices. Which value should I pass?

Solution: The Traditional NI-DAQ (Legacy) Function Reference Help should indicate that you must pass a value of -2 to achieve the .2 gain when using the following functions:
  • AI_Read
  • >AI_VRead
  • DAQ_VScale
  • AI_Setup
  • DAQ_Op
  • DAQ_Start
  • DAQ_Start
  • DAQ_to_Disk


Related Links:

Attachments: