DAQCard-1200, PCI-1200, and Lab-PC-1200 Missing a Diode that Will Impact RSE Readings

Hardware: Legacy DAQ Devices>>Multifunction DAQ>>DAQCard-1200

Problem: Certain revisions of the DAQCard-1200, PCI-1200, and Lab-PC-1200 are missing a diode that will impact RSE (referenced single-ended) readings.

Solution: This has been fixed and the current shipping revisions (as of August 1997) are:
Product		Fixed Rev
DAQCard-1200 F
PCI-1200 F
LabPC-1200(/AI) E
If you have a revision of one of these boards that is earlier than the ones listed above, then please contact National Instruments technical support for assistance (see the Request Support link, below). Otherwise, you should not be affected by this problem if your board is this revision (or higher).