How Many Application Manager, ExecutionView Manager or SequenceFileView Manager Controls Do I Need?

Primary Software: TestStand
Primary Software Version: 3.0
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem: All of the shipping operator interfaces use a single SequenceView control to display one sequence file or one execution at a time. If I want to display multiple sequence files or multiple executions at a time, how many of each of the TestStand User Interface Manager controls do I need?

Solution: Any application that uses the TestStand UI Manager controls must have one Application Manager control along with one SequenceFileView Manager and ExecutionView Manager control for each location, such as a window, panel, or control, in which you may display a sequence file or let the user select a current sequence file.

For more information about TestStand UI Manager controls refer to Chapter 9, Creating Custom Operator Interfaces, in the TestStand Reference Manual. You can also find more information in the TestStand Help and on the TestStand User Interface Controls Reference Poster.

Related Links:

Attachments:





Report Date: 03/01/2004
Last Updated: 06/18/2004
Document ID: 37072N3J

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit