Unable to set GPIB-1014-1S SYSFAIL light green on Heurikon CPU board, version V2FA.

Hardware: GPIB>>Plug-in Controllers>>GPIB-1014

Problem: In a particular situation in which a Heurikon CPU board version V2FA was being used, there were problems encountered simply trying to set the SYSFAIL green on the GPIB-1014-1S. There was no problem using version V2F of the Heurikon board.

Solution: Heurikon changed the way the reset is done on the master control in version V2FA of their CPU boards. This causes a problem and requires a patch (replacement PAL chip from Heurikon (Madison, WI)).

Related Links:

Attachments:





Report Date: 05/08/1996