Common Error Codes for NI System Monitor v1.1

Primary Software: Other NI Software>>PXI Platform Services
Primary Software Version: 2.3.2
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
What are the common error codes and explanations of the NI System Monitor v1.1?

Solution:
The following are the meanings of the error codes for the NI System Monitor:
  • Error Code -25020
    (Hex 0xFFFF9E44) The device firmware version is incompatible with the driver version.
  • Error Code -25019
    (Hex 0xFFFF9E45) The device cannot be accessed because the machine is changing to a lower power state.
  • Error Code -25018
    (Hex 0xFFFF9E46) Reading the Rpm for the designated fan is not supported.
  • Error Code -25017
    (Hex 0xFFFF9E47) Error allocating memory for object.
  • Error Code -25016
    (Hex 0xFFFF9E48) Error in setting proxy blanket for WMI.
  • Error Code -25015
    (Hex 0xFFFF9E49) Could not connect to WMI.
  • Error Code -25014
    (Hex 0xFFFF9E4A) Failed to create IWbemLocator object.
  • Error Code -25013
    (Hex 0xFFFF9E4B) Failed to initialize the COM library.
  • Error Code -25012
    (Hex 0xFFFF9E4C) Insufficient user privilege to complete the requested operation.
  • Error Code -25011
    (Hex 0xFFFF9E4D) The operating system returned an unexpected error.
  • Error Code -25010
    (Hex 0xFFFF9E4E) The Chassis Monitor Module is in the incorrect slot.
  • Error Code -25009
    (Hex 0xFFFF9E4F) Some file or component that should have been installed is missing.
  • Error Code -25008
    (Hex 0xFFFF9E50) System information in pxisys.ini or pxiesys.ini does not match the resource string.
  • Error Code -25007
    (Hex 0xFFFF9E51) The pxisys.ini or pxiesys.ini file could not be found.
  • Error Code -25006
    (Hex 0xFFFF9E52) Object is not being monitored by the chassis or controller.
  • Error Code -25005
    (Hex 0xFFFF9E53) Buffer not large enough to hold all data.
  • Error Code -25004
    (Hex 0xFFFF9E54) The specified parameter is of incorrect type or format
  • Error Code -25003
    (Hex 0xFFFF9E55) The given session or object reference is invalid.
  • Error Code -25002
    (Hex 0xFFFF9E56) Invalid resource name specified.
  • Error Code -25001
    (Hex 0xFFFF9E57) The requested operation is not supported for the initialized resource.
  • Error Code -25000
    (Hex 0xFFFF9E58) Unknown error.

  • Error Code 24900
    (Hex 0x6144) Unknown Warning.
  • Error Code 24901
    (Hex 0x6145) The reading for the indicated fan is beyond the sensor's maximum range.
  • Error Code 24902
    (Hex 0x6146) The reading for the indicated fan is below the sensor's minimum range.
  • Error Code 24903
    (Hex 0x6147) The reading for the indicated temperature sensor is beyond the sensor's maximum range.
  • Error Code 24904
    (Hex 0x6148) The reading for the indicated temperature sensor is below the sensor's minimum range.
You are also able to find these NI System Monitor error codes at C:\Program Files\National Instruments\Shared\Errors\English\NI System Monitor-errors.txt