Adding Dynamic VIs to TestStand When Using the LabVIEW Report Generation Toolkit

Primary Software: TestStand
Primary Software Version: 4.0
Primary Software Fixed Version: N/A
Secondary Software: LabVIEW Toolkits>>Report Generation Toolkit for Microsoft Office

Problem:
The LabVIEW Report Generation Toolkit does not work properly with my TestStand deployment.

Solution:
This problem occurs because the LabVIEW Report Generation Toolkit uses the VI Server to launch a number of dynamic VIs. The VI Server looks for the dynamic VIs in the data folder of the executable that is going to use the VIs. In the case of TestStand is the folder is located at <TestStand>\Components\User\RuntimeServers\data.

The way to fix this problem is to copy all the files from <LabVIEW>\vi.lib\addons\_office to the <TestStand>\Components\NI\RuntimeServers\LabVIEW\data folder.

Note: If the data folder does not exist, then you can create one.

Related Links: