Error Trying to Configure CVS with Vision Builder for Automated Inspection 2.0 Primary Software: Vision Builder for Automated InspectionPrimary Software Version: 2.0 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I recently installed some new National Instruments drivers on my computer. I can still connect to my Compact Vision System (CVS) through Measurement & Automation Explorer and install software, but when I attempt to install the VBAI Server through Vision Builder for Automated Inspection (VBAI), I get this error message after I click on Configure: I tried deleting all the software from the CVS and installing again from VBAI, but I still get the same error. Why is this happening, and what do I need to do to correct it? Solution: This error occurs if your version of Measurement & Automation Explorer is updated from 3.0 to a newer version (like 3.1). This probably occurred when you were installing a different driver. To correct this problem, please upgrade your version of VBAI to version 2.0.2 or later. Related Links: Drivers and Updates: Vision, Current Versions National Instruments Image Acquisition and Vision Support Homepage Attachments:
Report Date: 05/13/2004 Last Updated: 05/14/2004 Document ID: 39CEHFMU |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||