NI 9870 Does not show up in FPGA IO ConstantPrimary Software: LabVIEW Modules>>FPGA ModulePrimary Software Version: 8.6 Primary Software Fixed Version: N/A Secondary Software: Driver Software>>NI-RIO Hardware: Serial>>RS-232>>NI 9870
Problem: I have placed an I/O constant or I/O control as the input to my FPGA I/O Method Node or FPGA I/O Property Node and want to select my 9870/9871 module or one of it's ports. Why does it not show up as one of the selections? Solution: FPGA I/O elements are part of the LabVIEW project. The 9870/9871 modules do not have FPGA I/O elements in the project and therefore do not support direct interaction with the I/O pins due to the RS-232 and RS-485/422 protocols. Because of this, they cannot be selected in an I/O constant or I/O control. To configure the Method or Property node for the 9870/9871 ports:
Related Links: Products and Services: NI 9870 Products and Services: NI 9871 Community: 9870/9871 Programmatically Switch Ports (cRIO) Attachments:
Report Date: 06/23/2009 Last Updated: 11/23/2009 Document ID: 4YM9N3UV |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||