Unable to Build for PDA Target Primary Software: LabVIEW Modules>>PDA ModulePrimary Software Version: 8.2 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I have installed Microsoft eMbedded Visual Tools but I still get an error saying "Error building executable. Unable to create file" while building for the Pocket PC 2003. Solution: This problem is usually caused in a computer where the PATH environment variable doesn't get set properly after installing Microsoft eMbedded Visual Tools. All you need to do is locate the executable link.exe for Microsoft eMbedded Visual C++, usually located in the Program Files directory and then determine its path and add it to the PATH environment variable. For example “C:\Program Files\National Instruments\LabVIEW 8.2\PDA\Utilities\VC\ce\bin\x86_arm”.
To add the path to your environment variable follow the following steps (this requires administrator privileges): Related Links: KnowledgeBase 2ZTAQ5DS: Where Can I Find the Microsoft Tools I Need for the LabVIEW PDA Module? Attachments:
Report Date: 03/19/2007 Last Updated: 03/21/2007 Document ID: 47ILRPJ6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||