Which PXI/SCXI Combo Chassis Support Using Parallel Mode for the SCXI Modules? Hardware: PXI/CompactPCI>>Chassis>>PXI-1011, PXI/CompactPCI>>Chassis>>PXI-1050, PXI/CompactPCI>>Chassis>>PXI-1010, PXI/CompactPCI>>Chassis>>PXI-1052
Problem: I want to get a PXI/SCXI Combo Chassis and I want to be able to set up my SCXI modules for parallel mode. Which PXI/SCXI Chassis support parallel mode? Solution: In order to run in parallel mode a cable must be connected from the front of the controlling data acquisition (DAQ) card to the back of the SCXI module. For this reason, only PXI/SCXI Combo Chassis where the backplane of the SCXI is open can be used in parallel mode. Combo Chassis that Support SCXI Modules in Parallel Mode Do Not Support SCXI Modules in Parallel Mode Related Links: KnowledgeBase 11T8ASHL: How Do I Read Channels in Parallel Mode on an SCXI Module? KnowledgeBase 2AE7GIQO: Which SCXI Modules are Capable of Running in Parallel Mode? KnowledgeBase 2BNAQ3OV: Can I Use SCXI Modules in Parallel Mode and Multiplexed Mode in the Same Chassis? KnowledgeBase 2FE8LBEW: Using the SCXI-1180 or SCXI-1181 Modules in a PXI Combination Chassis Attachments:
Report Date: 10/03/2005 Last Updated: 10/03/2005 Document ID: 3Q2ES346 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||