SPC Toolkit's SPCSetChartPlotAttributes() Causes a General Protection Fault

Primary Software: LabWindows/CVI Add-ons>>Statistical Process Control Toolkit
Primary Software Version: 1.1
Primary Software Fixed Version: N/A
Secondary Software:

Problem: When I use the SPCSetChartPlotAttributes() function panel to generate code I sometimes receive a General Protection Fault when executing the resulting line. The parameters on the panel appear to be in the incorrect order. What is the correct ordering of parameters?

Solution: The correct parameter order is Panel, Graph Control, Plot Class, Plot Style, Point Style, Line Style, and finally, Color.

This problem has been fixed in the SPC Toolkit version 1.1.1. For earlier versions, simply reorder the parameters manually.

Related Links:

Attachments:





Report Date: 08/10/1998
Last Updated: 11/03/2003