Can I Have the Same Cable for Multiple CAN Speeds? Hardware: Industrial Communications>>CAN>>PXI-8464/1 Series 2, Industrial Communications>>CAN>>PCI-CAN/XS Series 2, Industrial Communications>>CAN>>PCI-CAN/XS, Industrial Communications>>CAN>>PCI-CAN/XS2, Industrial Communications>>CAN>>PCI-CAN/XS2 Series 2
Problem: I have a software selectable NI-CAN card that allows me to have high speed, low speed/fault-tolerant, and single-wire CAN. Do I need a different cable to communicate with each mode? Solution: Since each different mode has different termination, you will need a different cable for each. See the related links below for proper termination. Note: If the cable is short, you can use the non-terminated cable for both. This should work up to 1 meter. However, there is still a risk using a cable with no termination with high speed CAN. This may work with short cables, but it could still fail depending on the environmental noise. Related Links: KnowledgeBase 3IABNOHS: Proper Termination for NI-CAN Hardware Product Manuals: NI-CAN Hardware and Software Manual Attachments:
Report Date: 11/20/2006 Last Updated: 02/09/2007 Document ID: 43JD8P0D |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||