LabVIEW Code Generation in SignalExpress Fails

Primary Software: LabVIEW SignalExpress>>Development System
Primary Software Version: 1.0
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
I have built a SignalExpress project and would like to move this code to LabVIEW for further development. I have tried selecting Tools»Generate Code»LabVIEW Diagram. When I do this, nothing happens. How can I export my code to LabVIEW?

Solution:
SignalExpress interacts with LabVIEW using the VI Server.  In order to use the code generation capability of SignalExpress, you must enable access to the VI Server in LabVIEW. Follow these steps to allow SignalExpress full access to LabVIEW.
  1. Open your version of LabVIEW.
  2. Select Tools»Options.
  3. Navigate to the category VI Server: Exported VIs.
  4. Select Add and type *.* in the Exported VIs box. 
  5. Ensure the Allow Access radio box is checked.
  6. Select OK to close the Options window and save your settings.
Now you will be able to generate code in LabVIEW from SignalExpress.

Please note that if there are error messages shown when the code generation fails, you may need to consult other KBs, such as KnowledgeBase 492G4A9S: LabVIEW SignalExpress Code Generation Does Not Work after Upgrading LabVIEW.

Related Links:
KnowledgeBase 492G4A9S: LabVIEW SignalExpress Code Generation Does Not Work after Upgrading LabVIEW
KnowledgeBase 491ET584: LabVIEW SignalExpress Code Generation and NI LabVIEW Base Development System Compatibility
KnowledgeBase 47TGOST7: Express VI Created by Code Generation Feature in LabVIEW SignalExpress