On the VXI/VME-MXI, how should I Set the VMEbus Controller Bus Timeout Jumper Setting?

Primary Software: Driver Software>>NI-VISA
Primary Software Version: 1.2
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: VXI/VME/MXI>>MXI Interfaces>>NB-MXI

Problem: On the VXI/VME-MXI, how should I set the VMEbus Controller Bus Timeout jumper setting?

Solution: If possible, you should always assign the VXI/VME-MXI to be the device that monitors the VMEbus timeout period. You can use the VMEbus Controller Bus Timeout jumper setting to select a VMEbus timeout period of 100, 200, or 400 microseconds. The default VMEbus timeout period is 100 microseconds. If another VXI/VME device must monitor the VMEbus timeout period, set the VXI/VME-MXI's VMEbus Controller Bus Timeout jumper setting to DISABLE.