Error 1 Using NI ELVIS Source Code With LabVIEW 7Primary Software: Driver Software>>NI ELVIS Driver VIsPrimary Software Version: 1.0 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: When I try to run the ELVIS - Instrument Launcher VI or the ELVIS - Function Generator VI source code of NI ELVIS within LabVIEW 7 I receive Error 1 occurred at Property Node (arg 1) described by the following popup How can I eliminate this error? Solution: This error only occurs in LabVIEW 7. LabVIEW 7 handles the window bounds property differently than LabVIEW 6.1. To eliminate this error you need to reduce the minimum panel size of these two VIs within the VI Properties (File>>VI Properties>>Window Size). For the ELVIS - Instrument Launcher VI, the minimum panel size is preset to 260 x 444 and should be changed to be 240 x 400 or smaller. For the ELVIS - Function Generator VI, the minimum panel size is preset to 425 x 331 and should be changed to be 400 x 300 or smaller. Related Links: Attachments:
Report Date: 08/13/2003 Last Updated: 08/01/2008 Document ID: 30CFBQ0T |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||