Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
1 ratings:
 5 out of 5     Rate this Document

TestStand Won't Load After Crash: Error 80004005

Primary Software: TestStand
Primary Software Version: 4.0.1
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:

My TestStand crashed and now when I try to reopen it, I get the following error and it won't open:

Creating an instance of the COM component with CLSID {B2794EF6-C0B6-11D0-939-0020AF68E893} from the IClassFactory failed due to the following error: 80004005

How can I fix this?



Solution:

This error can occur if your StationGlobals.ini file has become corrupted and could not be loaded when TestStand opens.

To fix this, simply delete or rename the StationGlobals.ini file. This file is located in:
<Program Files>\National Instruments\TestStand x.x\Cfg
The next time you open up TestStand, a new default copy of StationGlobals.ini will be created.

Note: This will erase the Station Globals that you had set up on your computer and you will have to recreate them. Also, its always good practice to save a backup of your files before deleting them.



Related Links:

Attachments:





Report Date: 03/10/2008
Last Updated: 03/10/2008
Document ID: 4J9G47PE

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit