No Refresh when Cursor Events are Processed in DIAdem VIEW Primary Software: DIAdemPrimary Software Version: 10.1 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: The VIEW Cursor event is used to modify the data in channels and to display the data in a 2D axis system. Due to the high access speed, DIAdem uses the CHDX function to modify the data. However, the data displayed in the 2D axis system is not the actual modified data. Solution: To access
channel values
faster with the CHDX function, DIAdem does not automatically refresh
the
channel values for this function. The characteristic channel values
indicate to
DIAdem whether the displays in VIEW are to be refreshed. Therefore, at
least one
channel value per channel must be generated with the CHD function, in
order for
the characteristic channel values to be calculated. Alternatively,
you can
use the CHNCHARACTER command to recalculate the characteristic channel
values,
after all the channel values have been modified. Related Links: Attachments:
Report Date: 07/10/2006 Last Updated: 01/09/2007 Document ID: 3Z9994I9 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||