Problems with the NI-670x Family of Analog Output Boards and NI-DAQ 6.9.2 Primary Software: Driver Software>>NI-DAQPrimary Software Version: 6.9.2 Primary Software Fixed Version: 6.9.3 Secondary Software: N/A Hardware: Signal Sources (AWG/FG/AO)>>Analog Output Devices>>PCI-6703, Signal Sources (AWG/FG/AO)>>Analog Output Devices>>PXI-6703, Signal Sources (AWG/FG/AO)>>Analog Output Devices>>PXI-6704, Signal Sources (AWG/FG/AO)>>Analog Output Devices>>PCI-6704
Problem: The PCI-6703, PXI-6703, PCI-6704, and PXI-6704 become inoperable when NI-DAQ 6.9.2 is installed from the LabVIEW 6.1 (English-only) CD. The devices do not pass the Resource Test in the Measurement & Automation Explorer (MAX). Solution: The version of the NI-DAQ driver that shipped with LabVIEW 6.1 (nidaq 6.9.2f4) does not support the PCI-670x family. NI-DAQ version 6.9.3 supports the cards. The solution to this problem is to uninstall the current driver and download and install NI-DAQ 6.9.3 from the NI website. (see the related link below). Related Links: Drivers and Updates: NI-DAQ 6.9.3 for Windows Attachments:
Report Date: 01/09/2002 Last Updated: 06/23/2004 Document ID: 2H8HM49V |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||