The Example "pareto2.prj" for the Statistical Process Control (SPC) Toolkit 1.1.1 Causes a General Protection Fault When Changing Chart Attributes Primary Software: LabWindows/CVI Add-ons>>Statistical Process Control ToolkitPrimary Software Version: 1.1 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: When running the "pareto2.prj" project, if you click on the apply button in the User Interface, it will cause a general protection fault. This is because in the initial setup of the application it generates the SPC values to be used in the chart and then destroys them after drawing them on the chart. This is correct. However, these values need to be recreated before being redrawn when you press the apply button and then destroyed after drawing each time the button is pressed. Solution: Attached is the project with the necessary corrections. Related Links: Attachments:
Report Date: 12/04/2000 Last Updated: 12/07/2004 Document ID: 243FTDDD |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||