Modifying the Login Callback VI of the LabVIEW Test Executive Produces a Runtime Error Stating Could not call the Login System Callback

Primary Software: LabVIEW Toolkits>>Test Executive
Primary Software Version: 5.1
Primary Software Fixed Version: N/A
Secondary Software: LabVIEW Development Systems

Problem: I have created my own Login Callback.vi for use with the LabVIEW Test Executive. I still have three user levels (i.e. developer, technician and operator). I have also modified the testexec.ini file to point to newly modified Login Callback.vi. However, when I attempt to launch the LabVIEW Test Executive I receive the following error:
  • Runtime Error(s):
  • Could not call the Login System Callback.
  • Property Node (arg1) in Call Login Callback.vi ->Test Executive
What am I doing incorrectly?

Solution: You will receive this error if you have not created a connector pane for the Login Callback.vi. At the least you should have the Current Login Info, New Login Info and Error Cluster wired to the connector pane.

Related Links:

Attachments:





Report Date: 12/02/1998
Last Updated: 06/04/2004
Document ID: 1G19DSPR