Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
4 rating:
 1 out of 5     Rate this Document

VirtualBench-Scope 2.1.1 and 2.1.2 Don't Recognize the PXI-5102 or PCI-5102 with NI-DAQ 6.5 or Higher

Primary Software: Other NI Software>>VirtualBench
Primary Software Version: 2.5
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem: VirtualBench-Scope 2.1.1 and 2.1.2 don't recognize the PXI-5102 or PCI-5102 with NI-DAQ 6.5 or higher.

Solution: Starting in NI-DAQ 6.5, the PXI-5102 and PCI-5102 are recognized by the system as "NI 5102" instead of by their former names of "PCI-5102" or "PXI-5102". Since VirtualBench 2.1.1 and 2.1.2 were written before NI-DAQ 6.5, they don't search for "NI 5102"; therefore, they don't recognize the cards. VirtualBench 2.5 (or higher) recognizes the new format.

The workaround is to upgrade VirtualBench or downgrade NI-DAQ to 6.1.1

Related Links: VirtualBench Upgrade Information

Attachments:





Report Date: 12/01/1998
Last Updated: 12/05/2004
Document ID: 1G09N8TL

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit