Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
4 ratings:
 3.25 out of 5     Rate this Document

A VI With Reference to USB-8451 Crashes LV8.5/8.5.1 When Opened/Run from a Project

Primary Software: LabVIEW Development Systems>>Base Package
Primary Software Version: 8.5
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
I created a VI in LabVIEW 8.5/8.5.1 that references the NI-845x resource control. LabVIEW project is crashes the VI is opened/run from the Project Explorer. When opened as a single VI (not as a part of a project) the VI works fine. How can I fix this?

Solution:
To fix this issue you can go into LabVIEW 8.5/resource/objmgr and find the NI845x.rc file. Modify the "loadFunction: ni845xLVLoadFunc" line to place '/////' (5 forward slashes and no quotations) in front.

You may also replace your existing NI845x.rc file with the attached NI845x.rc file, which has the fix implemented.

Related Links:

Attachments:


NI845x.rc


Report Date: 02/26/2008
Last Updated: 06/13/2008
Document ID: 4IPG7TJL

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit