A VI With Reference to USB-8451 Crashes LV8.5/8.5.1 When Opened/Run from a Project Primary Software: LabVIEW Development Systems>>Base PackagePrimary Software Version: 8.5 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I created a VI in LabVIEW 8.5/8.5.1 that references the NI-845x resource control. LabVIEW project is crashes the VI is opened/run from the Project Explorer. When opened as a single VI (not as a part of a project) the VI works fine. How can I fix this? Solution: To fix this issue you can go into LabVIEW 8.5/resource/objmgr and find the NI845x.rc file. Modify the "loadFunction: ni845xLVLoadFunc" line to place '/////' (5 forward slashes and no quotations) in front. You may also replace your existing NI845x.rc file with the attached NI845x.rc file, which has the fix implemented. Related Links: Attachments:
Report Date: 02/26/2008 Last Updated: 06/13/2008 Document ID: 4IPG7TJL |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||