NI VLM Volume License Installer Causes Error -12 When Building Distribution in Application BuilderPrimary Software: Other NI Software>>NI Volume License ManagerPrimary Software Version: 2.1 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Toolkits>>Application Builder, LabWindows/CVI Development Systems>>Base Package, TestStand
Problem: I installed an Application Development Environment (ADE), such as LabVIEW, LabWindows\CVI, or TestStand, from a Volume License Manager (VLM) Volume License Installer. Now, I'm building a distribution of an application I wrote in this ADE, and I am including an Additional Installer of an NI component. I receive Error code -12: The system cannot find the path specified.
Solution: Locate the original installer, as opposed to the NI VLM volume license installer, of the product mentioned just before the error message (Notice the build fails when copying LabVIEW 8.5.1 in the above screenshot). In the application builder of your ADE, change the Installer Source Location for each additional installer from the volume license installer location to its original installer location.
Then:
Report Date: 02/11/2008 Last Updated: 03/31/2009 Document ID: 4IAG99NM |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||