Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
1 rating:
 1 out of 5     Rate this Document

Issues Fixed in DIAdem 10.2.1

Primary Software: DIAdem
Primary Software Version: N/A
Primary Software Fixed Version: N/A
Secondary Software: DIAdem

Problem:
What bugs and other issues have been fixed in DIAdem 10.2.1?

Solution:
This KnowledgeBase article details the issues fixed in DIAdem 10.2.1.

General

492B7A6D          In the Numeric Format dialog box, the entry field for the format of the user-defined type has been enlarged.
4D3967HL The ValueRangeGet method of the OLE interface "DIAdem.TODataSheet" is now faster.
4DA9MUMH In the licensing area, DIAdem did not display some of the warnings and error messages completely.
4C92DWJ If DIAdem or the DataFinder Server Edition were installed on a machine where LabVIEW was also installed, LabVIEW incorrectly displayed the DataFinder as an additional installer in the Installer Properties field of the build specifications.
3Q3A22RR When DIAdem restarts, DIAdem now also uses the time format set under General Settings in the entire DIAdem user interface and for the script commands RootPropGet, GroupPropGet, ChannelPropGet, RootPropSet, GroupPropSet, and ChannelPropSet. If you enter an invalid format, DIAdem uses the standard DIAdem format of the specific DIAdem user interface language.

DataFinder

47KEA2GX          In rare cases, the DataFinder crashed as soon as the computer started or after the user logged on.

Data Portal

4DHELOK7          If you wanted to move one or more channels below the last channel on the List tab in the Data Portal, DIAdem crashed.

NAVIGATOR

4DC92939          If a filter was activated in the ASAM Data Service, DIAdem did not always save all the modified data on the server with the OdsCommit command.
4DKFR139 An incorrect Enum declaration in ATF/XML files sometimes caused an infinite loop in DIAdem.
4CLBHM39 DIAdem again displays the calendar as an entry help in the ASAM filter dialog box.
4ACCR8T4 VBS DataPlugins that included the AddStoreChannel command crashed when they processed implicit channels.
4A38S6QA The size of the controls in the Excel Import Wizard and the Excel Export Wizard has been adjusted.
4A0H5K6D VBS DataPlugins that used the FixedWidthBlock objects were accelerated for large blocks in particular.
4D6AASQP The ATFX Plugin now also supports DT_LONG-type data.
4EFEGQQP DIAdem did not display several errors that occurred when a faulty measurement was imported in the ASAM data service. DIAdem now displays these errors.

ANALYSIS

48MAIRKP          If channels with a maximum length of one value were used in calculations, the ChnCalculate command produced an error and DIAdem consequently crashed.
48OG28KO The size of several of the ANALYSIS dialog boxes has been adjusted for Windows Vista.
4BIACTKO In frequency-weighted acceleration (command ChnAccelWCalc) the Wb evaluation filter was identified as ISO 2631-4. However, DIAdem executed the calculation according to DIN 45671. The identification has been changed and both calculation types are now available.

REPORT

4D4G88KO          In the dialog box for setting 2D table scaling, where the table length was set as Automatic expand, the Start at row entry was not always visible.
4ARGABKO If dynamic data management was not set, curve transformation did not always function correctly.
4DDF2RKO In 3D axis systems, you can also label isolines in an XY-view that is rotated to any point around the z-axis, in the display modes Surface and Characteristic Diagram. A characteristic diagram can now also be clipped to a boundary curve in an XY-view that is rotated to any point around the z-axis.
4AC2J8Q3 If you combined curve transformation and curve smoothing, DIAdem did not always delete all temporary channels.
4B30O3SJ In the Template.tdr template file, the setting Expand curves was activated, which was incorrect. This meant that layouts could not always be transferred from VIEW to REPORT.
4C7F0AKO The curve end labels disappeared if the Do not cut curve checkbox was selected.
491EIUQA In 2D axis systems, you could sometimes not switch between Range and Bars, in the display modes Differential, Spikes, Bars, Horizontal Spikes, and Horizontal Bars.
4DG941K7 If you double-clicked small text objects, DIAdem sometimes crashed.
49MBKJK7 If the data is in a matrix format, DIAdem can now also display markers in the characteristic diagram. 
4AEEAEKO If more than one curve entry was defined, the 3D color legend sometimes used an incorrect color palette.

SCRIPT

496CTM6X          In user dialog boxes, DIAdem completed texts incorrectly in editable, sorted Comboboxes.
4989RB6X In user dialog boxes, setting the Value property in an editable, sorted Combobox resulted in incorrect values.

VISUAL

4D291PQ8          Color shading that was defined with a color and a brightness value displayed different color shading than previously, because the brightness variable did not function correctly. The higher the brightness value the darker the color shading, and vice versa.

DAC

4CUD17LC          Accessing GPIB devices at addresses higher than 15 caused problems, because NI-488.2 drivers often either rejected the addresses or did not recognize them.



Related Links: KnowledgeBase 4LNHOF6X: What's New in DIAdem 10.2 and DIAdem 10.2.1?

Attachments:





Report Date: 10/09/2008
Last Updated: 10/10/2008
Document ID: 4Q8FCAQX

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit