Do the E-Series Analog Output Digital Triggering Examples in LabVIEW Work with the 671x Family of Analog Output Boards? Primary Software: LabVIEW Development Systems>>Full Development SystemPrimary Software Version: 7.1 Primary Software Fixed Version: N/A Secondary Software: Driver Software>>NI-DAQ Hardware: Multifunction DAQ (MIO)>>E Series>>PCI-MIO-16E-1, Multifunction DAQ (MIO)>>E Series>>PXI-6071E, Multifunction DAQ (MIO)>>E Series>>DAQPad-6070E for IEEE 1394 w/Mass Term, Legacy DAQ Devices>>Multifunction DAQ>>AT-MIO-16E-1, Multifunction DAQ (MIO)>>E Series>>DAQPad-6070E for IEEE 1394 w/BNC Term, Multifunction DAQ (MIO)>>E Series>>PCI-6071E, Multifunction DAQ (MIO)>>E Series
Problem: I have a 671x board and I want to use digital triggering. Can I use the E-Series analog output digital triggering examples that ship with LabVIEW? Solution: Yes. You just need to change the PFI pin number from 0 to 6 in "Trigger Parameters" under the "trigger or gate source specification" control. Related Links: Product Catalog - PCI-6711 Product Catalog - PCI-6713 Product Catalog - PXI-6711 Product Catalog - PXI-6713 Attachments:
Report Date: 06/12/2000 Last Updated: 01/27/2006 Document ID: 1YBFBIQI |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||