Problem: How is it possible for DASYLab to control a relay depending on two different signals for start and stop?

Solution: The Combi Trigger is available in two versions: Start and Stop on One Channel and Start and Stop on Two Channels. Use the second version if you need to control a Relay with two independent data channels. The trigger has two inputs for every output: the input with the lower number is to monitor the start condition and the input with the higher number is for monitoring the stop condition.

Related Links: DASYLab Support Page
KnowledgeBase 318FDT2G. Using Triggers and Relays in DASYLab.