Using SCXI-1127/1128/1129 with NI-SWITCH 1.6.1 or earlier and NI Switch Executive 2.0 Primary Software: Driver Software>>NI-SWITCHPrimary Software Version: 1.6 Primary Software Fixed Version: 2.0 Secondary Software: Switch Executive
Problem: If you have NI-SWITCH 1.6.1 or earlier installed, when you add SCXI-1127-1128/1129 to an NISE 2.0 virtual device you will get an error. Solution: When trying to add an SCXI-1127/1128/1129 to a NISE 2.0 virtual device, a driver session and a logical name is created for all NI switches detected on the computer. In the Hardware Tab the Resource Descriptor will need to be changed from SCXx::y::INSTR (x is the chassis number, y is the slot number) to point to your switch module. Here are the possible instrument descriptors: Related Links: Attachments:
Report Date: 07/21/2004 Last Updated: 07/22/2004 Document ID: 3BKDO8HQ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||