Misleading Error -10444 with the NB-A2000 Primary Software: Driver Software>>NI-DAQPrimary Software Version: 4.9.4 Primary Software Fixed Version: N/A Secondary Software: N/A Hardware: Legacy DAQ Devices>>Analog Input>>NB-A2000
Problem: I have an NB-A2000 for my Macintosh. If I try to perform an odd number of scans on a single channel, I get error message -10444 that states that I do not having enough available memory. Solution: The NB-A2xxx boards cannot perform an odd number of scans on a single channel. To resolve the error, change the number of scans to an even number. Related Links: NI-DAQ and NI-DAQmx Base Driver Support for Mac OS Attachments:
Report Date: 12/06/1995 Last Updated: 02/24/2006 Document ID: 0G5GJA23 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||