Why does the TestStand Deployment Utility Display Internal Error Code -17306 when Building?



Primary Software:
Primary Software Version: 2010
Primary Software Fixed Version: 2010 SP1
Secondary Software: N/A

Problem:
I'm attempting to use the TestStand 2010 Deployment Utility to distribute my TestStand application. When I try to build the deployment, I receive the following error:

Internal error code -17306 Updating File Links
Unknown variable or property name 'Call'.
Error accessing item 'TS.SData.Call.AssemblyPath'. in TestStand - Get Step Property.vi->TestStand - Check Linkages in Step.vi->TestStand - Check Linkages in SubSteps.vi->TestStand - Search Sequence and Fix Linkages.vi->Fix Linkages in Sequence Files - TestStand.vi->TestStand - Fix Linkages.vi->TestStand - Build.vi->TestStand - Distribution Wizard GUI.vi->TestStand - Deployment Utility Splash Screen.vi


What is the cause of this error and how can I resolve it?

Solution:
This issue is fixed in TestStand 2010 SP1 and newer versions.

This error is caused by a bug in the TestStand 2010 Deployment Utility. The error occurs when your deployment contains custom step types with .NET substeps. You can install the NI TestStand 2010 f1 Patch to fix this behavior in TestStand 2010. For more information about other bug fixes included in the NI TestStand 2010 f1 Patch, please visit the following KnowledgeBase article:

KB 5KLDP8XU: TestStand 2010 f1 Patch Details

Related Links:
Drivers and Updates: NI TestStand 2010 f1 Patch
KnowledgeBase 5KLDP8XU: TestStand 2010 f1 Patch Details

Attachments:





Report Date: 03/28/2011
Last Updated: 03/03/2017
Document ID: 5JRDA2XU

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit