Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
1 rating:
 1 out of 5     Rate this Document

VI Logger 2.0 can not run tasks under MAX 4.0

Primary Software: Other NI Software>>VI Logger
Primary Software Version: 2.0
Primary Software Fixed Version: 2.0.1
Secondary Software: N/A

Problem: Whenever I create a VI Logger task and click "Run Task", I get error 4501 indicating the VI Logger task is already running, even though I just created the task. I've seen it with DAQmx 7.2, 7.5 and 8.0. I only have this problem with MAX 4.0 and do not see it with MAX 3.1.1.

I tried refreshing in MAX, re-running MAX, creating new VI Logger tasks, creating new DAQmx tasks, rebooting, etc. The error is still occurring. How can I fix this problem?

Solution: This error can be caused by having a previous version of VI logger installed. DAQmx only installs VI Logger Lite, and will not install over a full installation of VI Logger. To fix this problem, uninstall both DAQmx and VI Logger, and then re-install the DAQmx driver. This will install the correct version of VI Logger, and will fix the issue.

Related Links:

Attachments:





Report Date: 10/12/2005
Last Updated: 04/20/2006
Document ID: 3PRFPLXR

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit