LabVIEW 2012 SP1 f5에서 해결된 문제ID | 설명 |
416146 | Intermittent crashes or hangs can occur when two threads try to access the same resource at the same time. |
360229 | Class VI ,with source only turned on, loaded before a property accessor for a dynamic property it uses is broken on load. |
369472 | Polymorphic VIs lose their icons when built into packed libraries. |
381638 | Waveform chart X-Axis scales incorrectly when Plot Area scrolls for new data in LabVIEW 2012. |
404983 | Dynamic load of LabVIEW Class fails when built into a DLL. |
423373 | Under certain conditions, a compiler optimization will cause array shift registers to share memory space. |
ID | 설명 |
409185 | TestStand operator interfaces with VIs that run in the LabVIEW 2012 SP1 f3 Run-Time Engine are slow to quit. |
407860 | DVR Bad Reference Error when DVRs are being created/destroyed in parallel from different VI hierarchies. |
408844 | Memory growth observed when using Asynchronous Call By Reference node in long running loop. |
408845 | Measurement speed can degrade when using Asynchronous Call By Reference node in long running loop. |
ID | 설명 |
396984 | Sequential For Loop structures will sometimes execute incorrectly when the VI property "Allow Debugging" is unchecked in LabVIEW 2012. |
390386 | LabVIEW HTTP Client does not implement Curl Rewind causing authentication errors for auth-basic. |
384576 | NI SSL Libraries are not installed for the LabVIEW Run-Time Engine on Mac OS X. |
381193 | Application Builder Additional Installer section lists LabVIEW Run-Time Engine 2012 SP1 (64-bit) without the "SP1". |
ID | 설명 |
397249 | The LabVIEW 2012 SP1 f1 Patch breaks the Update VI Tool in TestStand and can cause existing LabVIEW steps in TestStand to throw an error. |
ID | 설명 |
389295 | LabVIEW 2012 SP1 breaks custom prototypes in DLLs that contain LabVIEW classes. |
381193 | The Render to Image method for 3D picture controls demonstrates slow performance, which can impact the update rates of 3D picture controls. |
|