NI 6515などの工業用デジタルIOの電源投入時状態の設定方法ハードウェア: Digital I/O (DIO)>>Isolated>>PCI-6527, Digital I/O (DIO)>>Isolated>>PCI-6528, Digital I/O (DIO)>>Isolated>>PXI-6527, Digital I/O (DIO)>>Isolated>>PCI-6526, Digital I/O (DIO)>>Isolated>>PCI-6525, Digital I/O (DIO)>>Isolated>>PCI-6513, Digital I/O (DIO)>>Isolated>>PXI-6526, Digital I/O (DIO)>>Isolated>>PCI-6515, Digital I/O (DIO)>>Isolated>>PXI-6512, Digital I/O (DIO)>>Isolated>>PXI-6514, Digital I/O (DIO)>>Isolated>>PXI-6523, Digital I/O (DIO)>>Isolated>>PXI-6521, Digital I/O (DIO)>>Isolated>>PXI-6513, Digital I/O (DIO)>>Isolated>>PXI-6522, Digital I/O (DIO)>>Isolated>>PXI-6515, Digital I/O (DIO)>>Isolated>>PCI-6519, Digital I/O (DIO)>>Isolated>>PCI-6518, Digital I/O (DIO)>>Isolated>>PCI-6516, Digital I/O (DIO)>>Isolated>>PCI-6512, Digital I/O (DIO)>>Isolated>>PCI-6522, Digital I/O (DIO)>>Isolated>>PCI-6514, Digital I/O (DIO)>>Isolated>>PXI-6528, Digital I/O (DIO)>>Isolated>>PCI-6517, Digital I/O (DIO)>>Isolated>>PXI-6525, Digital I/O (DIO)>>Isolated>>PCI-6521
問題: NI 6515などの工業用デジタルIOの電源投入時状態の設定はどのように行いますか? 解決策: NI 6515などの工業用デジタルIO(DIO)ボードでは、 電源投入時状態の設定を行うことができます。 その方法は以下のようになります。 1.Measurement & Automation Explorer(MAX)を開きます 2.デバイスとインターフェースのDAQmxの項目を開きます 3.設定したいDIOデバイスを選び、右クリックします。 4.右クリックメニューの中からプロパティを選びます。 5.起動状態の設定シートの中で状態を設定します。 設定した起動時の状態は、ボード上のEEPROMに書き込まれます。 関連リンク: プロダクトリファレンス:マニュアル(英語): Digital I/O Help for 6509/651x/6520/6521/6528 Devices (User Manual and Specifications) 添付:
報告日時: 12/08/2005 最終更新日: 12/22/2005 ドキュメントID: 3S7KE8V |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||