Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

What is the Correct Driver to Use With My NI 9213 Module?

Hardware: CompactRIO>>Analog Input Modules>>NI 9213

Problem:
What is the correct driver to use with my NI 9213 module?

Solution:
To verify your current driver version and determine if an upgrade is necessary, open up Measurement & Automation Explorer and expand the Software section.

CompactRIO Systems
All CompactRIO systems require NI-RIO 3.1.1 or later for use with the NI 9213 module.
 
CompactDAQ (cDAQ-9172) & USB-9162 Systems
All CompactDAQ and USB carrier systems require NI-DAQmx 8.9 or later for use with the NI 9213 module.

Wi-Fi (WLS-9163) & Ethernet (ENET-9163) Systems
All Wi-Fi and Ethernet systems require NI-DAQmx 8.9 or later for use with the NI 9213 module.

Note:  If you are using NI-DAQmx 8.9 with either the WLS-9163 or the ENET-9163 you must download and install the NI-DAQmx Patch for NI-9213WLS/ENET Temperature Offset. This patch is not WHQL signed, and should only be installed when using the NI 9213 with the Wi-Fi and Ethernet carriers. After installing this patch, administrative privileges may be required when installing some National Instruments USB devices on the system.

Note about NI-DAQmx 8.9: The MAX and DAQ Assistant connection diagram for the NI 9213 in NI-DAQmx 8.9 is incorrect. Refer to the NI 9213 operating instructions for the correct module pinout.

Related Links:
Drivers and Updates: NI-RIO
Drivers and Updates: NI-DAQmx
Drivers and Updates: NI-DAQmx 8.9 Patch 1

Attachments:





Report Date: 05/12/2009
Last Updated: 05/28/2009
Document ID: 4XBD1OQA

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit