How Can I Access the Second Drive on a NI Real-Time Controller Through Internet Explorer or MAX?Primary Software: LabVIEW Modules>>Real-Time ModulePrimary Software Version: 7.0 Primary Software Fixed Version: N/A Secondary Software: Utility Software>>Measurement & Automation Explorer
Problem: How can I access the second drive on a NI Real-Time Controller Through Internet Explorer or MAX? Solution: NI Real-Time controllers with LabVIEW Real-Time 7.0 can have the C: and D: drive directly accessed over FTP. To FTP into a Real-Time controller through Internet Explorer, use the following syntax :ftp://ip_address/. This URL will take you to the C drive of the controller. To access the compact flash memory allocated in the D drive, use the following syntax ftp://ip_address/d:/ In Measurement and Automation Explorer (MAX)
Note:This knowledgebase applies to RT devices that physically have multiple drives. It is does not work for drives with multiple partitions. Related Links: Attachments:
Report Date: 07/09/2003 Last Updated: 09/22/2004 Document ID: 2Z89SHHW |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||