Changing the Startup Graphic on NI TPC-2006, TPC-2106 and TPC-2012
Hardware: Industrial Communications>>HMI and Industrial PC>>TPC-2006, Industrial Communications>>HMI and Industrial PC>>TPC-2106, Industrial Communications>>HMI and Industrial PC>>TPC-2012
Problem: How can I replace the default startup graphic on the NI TPC-2006, TPC-2106 or TPC-2012?
Solution: You can replace the default startup graphic with your own by following these steps:
TPC-2006:
- Create a bitmap file that is 320 x 240 x 8bpp
- Save this file as logo60s.bmp
- Make sure the CompactFlash card is blank (you can have folders on the CompactFlash but no other files directly on the root). Copy the file logo60s.bmp to the card
- Turn off the TPC-2006, insert the CompactFlash card, and power the TPC-2006 back up
- When prompted, power off the TPC-2006 and remove the CompactFlash card
- Restart the TPC-2006, and it will now use your bitmap file as the startup graphic
TPC-2106/TPC-2106T:
- Modify the appropriate file attached (TPC-2106.bmp or TPC-2106T.bmp) to create your new splash screen. If you modify the file all the attributes are already set.
- Format a CF card as FAT-16 (FAT).
- Copy the modified bitmap to a CF card and rename it to bootlogo.bmp.
- Insert CF card into the device and boot.
- Follow the instructions on the device.
TPC-2012:
- Create a bitmap file that is 640 x 480 x 8bpp
- Save this file as boot.bmp
- In the directory \harddisk of the TPC-2012, rename the existing boot.bmp
- Copy boot.bmp to the \harddisk directory
- Restart the TPC-2012, and it will now use your bitmap file as the startup graphic
Related Links: NI LabVIEW Touch Panel Module KnowledgeBase 4TPG1Q6C: How Do I Change The Boot Screen on my XP Embedded Touch Panel?
Attachments:
TPC-2106.bmp
TPC-2106T.bmp
- logo60s.bmp
Report Date: 08/03/2006
Last Updated: 04/09/2009