Changing the Startup Graphic on NI TPC-2006 and TPC-2012

Primary Software: LabVIEW Modules>>Touch Panel Module
Primary Software Version: 8.2
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Industrial Communications>>HMI and Industrial PC>>TPC-2012

Problem:
How can I replace the default startup graphic on the NI TPC-2006 or TPC-2012?

Solution:
You can replace the default startup graphic with your own by following these steps:

TPC-2006:
  1. Create a bitmap file that is 320 x 240 x 8 bpp
  2. Save this file as logo60s.bmp
  3. Make sure the CompactFlash card is blank (you can have folders on the CompactFlash but no other files directly on the root). Copy the file logo60s.bmp to the card
  4. Turn off the TPC-2006, insert the CompactFlash card, and power the TPC-2006 back up
  5. When prompted, power off the TPC-2006 and remove the CompactFlash card
  6. Restart the TPC-2006, and it will now use your bitmap file as a startup graphic

TPC-2012:

  1. Create a bitmap file that is (640 x 480 x 8bpp)
  2. Save this file as boot.bmp
  3. In the directory \harddisk of the TPC-2012, rename the existing boot.bmp
  4. Copy boot.bmp to the \harddisk directory
  5. Restart the TPC-2012, and it will now use your bitmap file as a startup graphic


Related Links:

Attachments:


logo60s.bmp - logo60s.bmp


Report Date: 08/03/2006
Last Updated: 11/29/2007
Document ID: 402A280F

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit