SCC-A10 Measurements Show Up As NRSE In MAX

Primary Software: Utility Software>>Measurement & Automation Explorer
Primary Software Version: 1.0.1
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: SCC>>Modules>>SCC-A10

Problem: I’m taking voltage measurements using a SCC-A10 which has two Differential analog input channels. When selecting these channels in Measurement & Automation Explorer, I only see the NRSE input configuration, why is this?

Solution: The SCC-A10 does have two Differential analog input channels. The voltage differences are measured inside the module and are each output as a single voltage. The SCC-A10 has four outputs: the voltage difference between input pins 1 & 2 (AI channel 0), the voltage difference between pins 3 & 4 (AI channel 1), AI Sense, and AI Ground. Therefore, the output of the SCC-A10 is NRSE, not Differential. The SCC-A10 Signal Connections diagram below demonstrates this.

SCC-A10 Signal Connections


Related Links: SCC-A10 Voltage Attenuator Module Manual


Attachments:


SCC-A10.jpg - SCC-A10.jpg


Report Date: 10/04/2006
Last Updated: 10/13/2006
Document ID: 423I4F4G

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit