16-bit MS-DOS Subsystem Error After Installing NI-488.2 Driver Primary Software: LabVIEW Development Systems>>Full Development SystemPrimary Software Version: 7.1 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Development Systems>>Base Package, LabVIEW Development Systems>>Professional Development System Hardware: GPIB
Problem: After performing a complete install of LabVIEW 7.1, I inserted my PCI-GPIB board and booted up my computer. When Windows asked for the driver again, I installed the NI-488.2 CD that was included with my PCI-GPIB board. I do not see my board when I check for it in Measurement & Automation Explorer (MAX). When I check the Device Manager, it shows up correctly as a National Instruments GPIB device. I tried to reinstall my software, but now I get this error when I reboot: 16 bit MS-DOS SubsystemSolution: The NI-488.2 driver CD is not necessary because a complete install of LabVIEW already contains NI-488.2 and MAX. When NI-488.2 was installed again, a different version of MAX and/or NI-488.2 was installed on top of the versions that were installed with LabVIEW 7.1. When trying to uninstall the software, only one version is uninstalled, so certain files may be left behind. This is why the error is seen. To solve this problem, try these steps:
Related Links: KnowledgeBase 2FTCNNBG: I Get a GPIB-VDD.DLL Error when Installing NI-DAQ KnowledgeBase 2DJFRS00: Why Do I Get a gpib-vdd.dll Error? Attachments:
Report Date: 06/30/2003 Last Updated: 05/07/2008 Document ID: 2YTACLMU |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||