ComponentWorks DAQ with the PCI-6527Hardware: Digital I/O (DIO)>>Isolated>>PCI-6527
Problem: I am trying to use the ComponentWorks (CW) DAQ function CWDI with the 6527 for change notification in Measurement Studio / Visual Basic 6.0. I get an error message that says that this is not supported by the device. Can I use CWDAQ for change notification with the PCI-6527? Solution: No. The CWDI function was designed for waveform buffered digital input using NI boards that are hardware timed. Since the PCI-6527 does not have this capability, you will need to use function calls to do change notification with the PCI-6527. See the example code linked below for a demonstration of change notification with the PCI-6527. Related Links: DevZone Example: 6527 Change Detection using Visual Basic Manuals: NI 6527 Product Manuals Attachments:
Report Date: 08/17/2004 Last Updated: 09/14/2007 Document ID: 3CGA8SW1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||