硬件: Multifunction DAQ (MIO)>>M Series>>PXI-6221, Multifunction DAQ (MIO)>>M Series>>PCI-6220, Multifunction DAQ (MIO)>>M Series>>PCI-6250, Multifunction DAQ (MIO)>>M Series>>PCI-6224, Multifunction DAQ (MIO)>>M Series>>PCI-6254, Multifunction DAQ (MIO)>>M Series>>PCI-6251, Multifunction DAQ (MIO)>>M Series>>PCI-6229, Multifunction DAQ (MIO)>>M Series>>PCI-6221, Multifunction DAQ (MIO)>>M Series>>PCI-6259, Multifunction DAQ (MIO)>>M Series>>PXI-6284, Multifunction DAQ (MIO)>>M Series>>PXI-6259, Multifunction DAQ (MIO)>>M Series>>PXI-6220, Multifunction DAQ (MIO)>>M Series>>PXI-6281, Multifunction DAQ (MIO)>>M Series>>PXI-6251, Multifunction DAQ (MIO)>>M Series>>PCI-6281, Multifunction DAQ (MIO)>>M Series>>PXI-6229, Multifunction DAQ (MIO)>>M Series>>PXI-6250, Multifunction DAQ (MIO)>>M Series>>PXI-6280, Multifunction DAQ (MIO)>>M Series>>PCI-6280, Multifunction DAQ (MIO)>>M Series>>PCI-6284, Multifunction DAQ (MIO)>>M Series>>PXI-6224, Multifunction DAQ (MIO)>>M Series>>PXI-6289, Multifunction DAQ (MIO)>>M Series>>PXI-6254

问题:

同时使用M系列板卡和SCXI模块的时候,我能否在Port 0上使用数字IO?



解答:

是的,没有用来和SCXI通信的数字IO线也能够被使用。

使用PCI设备的时候,Port 0的0.1.2三条线用着数字输出和SCXI通信,而第4条线用作通信的数字输入。因此Port0中剩余的数字线都能够用于数字输入和输出。可以使用SCXI-1349转接头,通过50引脚的线缆访问剩余的数字线。

在混合机箱中使用PXI设备通过背板总线去访问SCXI模块,STC2芯片上的SPI口用来和SCXI通信,因此,Port0上的所有的数字线都能够用来通过IO连接器和M系列采集卡连接访问。



相关链接: KnowledgeBase 3QNGTJSE: Using the Digital I/O Lines on an E or M Series DAQ Board While Controlling an SCXI Chassis
KnowledgeBase 3F7DNTNY: M-Series Breakout Pin Translations for the SCXI-1349 and SCXI-1346