Reflection on the Serial Lines for the PXI-8430Hardware: Serial>>RS-485>>PXI-8431/2
Problem: I am currently using the PXI-8430 and am seeing reflection on each of the serial lines. This is causing my program to function incorrectly. I have tried the COM port on the front of the PXI controller and do not see any reflection. What could be causing this issue? Solution: This issue has been seen when using an incorrect cable with the PXI-8430. Ensure that you are using a RS-232 cable to connect to the instrument and not a RS-485 cable. This should resolve the reflection problems that are seen. Related Links: Products & Services: NI PXI-8430/4 (RS232) Attachments:
Report Date: 01/08/2009 Last Updated: 12/01/2009 Document ID: 4T7ELOR7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||