PXIe-6536/7 Documentation and Driver Support Primary Software: Driver Software>>NI-HSDIOPrimary Software Version: 1.0 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I just purchased the PXIe-6536/7, is the documentation or driver support any different than the PCIe-6536/7? Solution: A new specifications document that includes both the PCIe and PXIe 6536/7 can be found in the related link section below. The PXIe-6536/7 requires DAQmx 8.5 or later (although the DAQmx readme does not currently list this device as supported). Additionally, the RTSI_7 connection line should only used for a sample clock and not to share triggers or timebases. Although you can configure RTSI_7 for many signals, you will only get desired results if it is used for a sample clock. In a later release of DAQmx you will only be able to export a sample clock to RTSI_7. Related Links: NI PXIe/PCIe-6536/6537 Specifications Attachments:
Report Date: 06/01/2007 Last Updated: 06/14/2007 Document ID: 4A0EF117 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||