How tight should I tighten the screw terminals on my SCB-68 connector block?

Hardware: Counter/Timers (TIO)>>Connectivity>>SCB-68

Problem: How tight should I tighten the screw terminals on my SCB-68 connector block?

Solution: The manufacturer of the screw connectors is Phoenix Contact. Their catalog suggests a torque of .5 to .6 N*m, which is equivalent to the following:

50 to 60 N*cm
0.37 to 0.44 ft*lb
4.43 to 5.31 in*lb
70.81to 84.97 in*oz
5 to 6 dN*m
5.10 to 6.12 kg*cm