我运行模拟输出和模拟输入的范例程序时,收到错误信息 "Error 200452 "



硬件: Multifunction DAQ (MIO)>>S Series>>PCI-6115

问题: Why do I see Error 200453 while trying to run the analog generation or analog measurement examples in LabVIEW?



解答: 不是所有的DAQ硬件设备都支持可重触发的。您可以在具有可重触发的范例中的硬件列表中去检查核实您的DAQ设备在不在其中(如下图所示),如果不在您的DAQ设备就因为不支持对属性节点 Start.Retriggerable 的操作,会使得您在运行该项范例程序时报错 Error -200452。

 

如果您的DAQ硬件设备不支持可重触发的性能,您可以参照这个 KnowledgeBase 的链接去了解如何创建一个替代的可重触发的测量任务。

相关链接: KnowledgeBase 15JBOEWW: How Can I Perform a Retriggerable Analog Acquisition?

附件:





报告日期: 09/29/2009
最近更新: 09/22/2010
文档编号: 51SEAHA3