Can I Connect to Multiple ARM Microcontrollers at the Same Time?

Primary Software: LabVIEW Modules>>Embedded Module for ARM Microcontrollers
Primary Software Version: 1.0
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
I have two ULINK2 JTAG connectors along with the Keil MCB2300 evaluation board and the Luminary Micro LM3S8962 evaluation board.  I want to connect both evaluation boards to my computer at the same time and download to them alternatingly.  However, I keep getting a µVision error when I run either of the project VIs.

Solution:
You cannot successfully communicate with any ULINK2 device when more than one is connected to your computer at the same time.  µVision begins to initialize, but the initialization fails shortly after beginning, as depicted in the three images below.

In order to download a program to multiple evaluation boards, you must physically disconnect your first controller from the ULINK2 JTAG connector after loading your program and then connect your second controller to the ULINK2 JTAG connector.  You may then load your program onto the second controller.

Related Links:
Getting Started with the LabVIEW Embedded Module for ARM Microcontrollers 1.0 for the Luminary Micro LM3S8962
Getting Started with the LabVIEW Embedded Module for ARM Microcontrollers 1.0 for the Keil MCB2300
LabVIEW Embedded Module for ARM Microcontrollers 1.0 Help

Attachments:





Report Date: 09/26/2008
Last Updated: 09/26/2008
Document ID: 4PPTPXY

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit