Error -200474 With Digital Frequency Example VIs Modified for Continuous AcquisitionPrimary Software: Driver Software>>NI-DAQmxPrimary Software Version: 8.10 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Development Systems>>LabVIEW Professional Development System Hardware: Multifunction DAQ (MIO)>>M Series>>PCI-6229
Problem: I modified the Meas Dig Frequency-Low Freq 1 Ctr example VI to acquire continuously, and unless there is a signal with a frequency greater than 100Hz, I get Error -200474. What is wrong and how can I fix it?Solution: For some DAQmx driver versions any input frequency below 100Hz yields this error, which is expected behavior by design. If you do not want your program to cease acquiring data in the absence of a signal (or a frequency below 100Hz), you can clear that specific error number with each iteration as shown in the block diagram below. You can also download the attached VI which has this workaround implemented. Related Links: Attachments:
Report Date: 05/25/2007 Last Updated: 06/06/2007 Document ID: 49OGKCLO |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||